The DuctPressureDropData type exposes the following members.
Methods
Name | Description | |
---|---|---|
Dispose |
Releases all resources used by the
DuctPressureDropData
|
|
Equals | (Inherited from Object .) | |
GetHashCode |
Serves as a hash function for a particular type.
(Inherited from
Object
.)
|
|
GetType |
Gets the
Type
of the current instance.
(Inherited from
Object
.)
|
|
ToString |
Returns a string that represents the current object.
(Inherited from
Object
.)
|
Properties
Name | Description | |
---|---|---|
CategoryId |
The category id of duct curves. It will be OST_DuctCurves, OST_FlexDuctCurves, or OST_PlaceHolderDucts.
|
|
Coefficient |
The coefficient of the duct.
|
|
Density |
The density of the duct.Units: (kg/ft³).
|
|
EquivalentDiameter |
The equivalent diameter of the duct. Units: (ft).
|
|
Flow |
The flow of the duct. Units: (ft³/s).
|
|
Friction |
The friction of the duct. Units: (kg/(ft²·s²)).
|
|
Height |
The height of the duct. If the duct is round, it will be equal to the diameter of the duct. Units: (ft).
|
|
HydraulicDiameter |
The hydraulic diameter of the duct. Units: (ft).
|
|
IsValidObject |
Specifies whether the .NET object represents a valid Revit entity.
|
|
Length |
The length of the duct. Units: (ft).
|
|
Level |
The calculation level of the system.
|
|
PressureDrop |
The pressure drop of the duct. Units: (kg/(ft·s²)).
|
|
ReynoldsNumber |
The reynolds number of the duct.
|
|
Roughness |
The roughness of the duct. Units: (ft).
|
|
Shape |
The profile type of the duct.
|
|
Velocity |
The velocity of the duct. Units: (ft/s).
|
|
VelocityPressure |
The velocity pressure of the duct. Units: (kg/(ft·s²)).
|
|
Viscosity |
The viscosity of the duct. Units: (kg/(ft·s)).
|
|
WidthOrDiameter |
The diameter of the duct with round profile, or the width of the duct with other profiles. Units: (ft).
|