Create Method


Creates a new wire.

Namespace: Autodesk.Revit.DB.Electrical
Assembly: RevitAPI (in RevitAPI.dll) Version: 17.0.0.0 (17.0.484.0)
Since: 2015

Syntax

C#
public static Wire Create(
	Document document,
	ElementId wireTypeId,
	ElementId viewId,
	WiringType wiringType,
	IList<XYZ> vertexPoints,
	Connector startConnectorTo,
	Connector endConnectorTo
)
Visual Basic
Public Shared Function Create ( _
	document As Document, _
	wireTypeId As ElementId, _
	viewId As ElementId, _
	wiringType As WiringType, _
	vertexPoints As IList(Of XYZ), _
	startConnectorTo As Connector, _
	endConnectorTo As Connector _
) As Wire
Visual C++
public:
static Wire^ Create(
	Document^ document, 
	ElementId^ wireTypeId, 
	ElementId^ viewId, 
	WiringType wiringType, 
	IList<XYZ^>^ vertexPoints, 
	Connector^ startConnectorTo, 
	Connector^ endConnectorTo
)

Parameters

document
Type: Autodesk.Revit.DB Document
The document.
wireTypeId
Type: Autodesk.Revit.DB ElementId
The id of the wire type of the newly created wire.
viewId
Type: Autodesk.Revit.DB ElementId
The view in which the wire is to be visible. This must be the id of a floor plan or reflected ceiling plan view.
wiringType
Type: Autodesk.Revit.DB.Electrical WiringType
Specifiies the wiring type for the newly created wire. The shape of the wire is determined by this value and the total number of points supplied via the vertexPoints and endpoint connectors. If the wiring type is WiringType.Arc:
  • If there are 2 total points supplied, the wire is a straight-line wire.
  • If there are 3 total points supplied, the wire is a circular arc wire.
  • If there are 4 or more points, the wire is a spline wire.
If the wiring type is WiringType.Chamfer, a polyline wire will be created connecting all the points.
vertexPoints
Type: System.Collections.Generic IList XYZ
The vertex point of the wire. If the startConnectorTo is a null reference ( Nothing in Visual Basic) , the first vertex of the vertexPoints will be the start point, otherwise, the start connector origin will be the start point. If the endConnectorTo is a null reference ( Nothing in Visual Basic) , the last vertex of the vertexPoints will be the end point, otherwise, the end connector origin will be the end point.
startConnectorTo
Type: Autodesk.Revit.DB Connector
The connector to which the wire start point connects. If a null reference ( Nothing in Visual Basic) , the start point connects to no existing connector. If set with a connector, the connector's origin will be added to the wire's vertices as the start point.
endConnectorTo
Type: Autodesk.Revit.DB Connector
The connector to which the wire end point connects. If a null reference ( Nothing in Visual Basic) , the end point connects to no existing connector. If set with a connector, the connector's origin will be added to the wire's vertices as the end point.

Return Value

The wire created.

Exceptions

Exception Condition
Autodesk.Revit.Exceptions ArgumentException wireTypeId is not a valid WireType id. -or- viewId does not represent a view valid for a Wire element. Either a floor plan or reflected ceiling plan is expected. -or- vertexPoints is not valid, because one or more points are coincident by comparing the X and Y of the points, or there are not at least two points including the connectors. -or- startConnectorTo cannot be connected to a wire, as it is not an electrical connector. -or- endConnectorTo cannot be connected to a wire, as it is not an electrical connector.
Autodesk.Revit.Exceptions ArgumentNullException A non-optional argument was NULL
Autodesk.Revit.Exceptions ArgumentOutOfRangeException A value passed for an enumeration argument is not a member of that enumeration
Autodesk.Revit.Exceptions DisabledDisciplineException None of the following disciplines is enabled: Mechanical Electrical Piping.

See Also