Create Method (Document, ElementId, ElementId, Connector, XYZ)


Creates a new duct that connects to the connector.

Namespace: Autodesk.Revit.DB.Mechanical
Assembly: RevitAPI (in RevitAPI.dll) Version: 17.0.0.0 (17.0.484.0)
Since: 2017

Syntax

C#
public static Duct Create(
	Document document,
	ElementId ductTypeId,
	ElementId levelId,
	Connector startConnector,
	XYZ endPoint
)
Visual Basic
Public Shared Function Create ( _
	document As Document, _
	ductTypeId As ElementId, _
	levelId As ElementId, _
	startConnector As Connector, _
	endPoint As XYZ _
) As Duct
Visual C++
public:
static Duct^ Create(
	Document^ document, 
	ElementId^ ductTypeId, 
	ElementId^ levelId, 
	Connector^ startConnector, 
	XYZ^ endPoint
)

Parameters

document
Type: Autodesk.Revit.DB Document
The document.
ductTypeId
Type: Autodesk.Revit.DB ElementId
The ElementId of the new duct type.
levelId
Type: Autodesk.Revit.DB ElementId
The level id for the new duct.
startConnector
Type: Autodesk.Revit.DB Connector
The first connector where the new duct starts.
endPoint
Type: Autodesk.Revit.DB XYZ
The second point of the new duct.

Return Value

The created duct.

Remarks

The new duct will have the same diameter and system type as the specified connector. The creation will also connect the new duct to the component who owns the specified connector. If necessary, additional fitting(s) are included to make a valid connection. If the new duct can not be connected to the next component (e.g., mismatched direction, no valid fitting, and etc), the new duct will still be created at the specified connector position, and an InvalidOperationException is thrown.

Exceptions

Exception Condition
Autodesk.Revit.Exceptions ArgumentException The duct type ductTypeId is not valid duct type. -or- The level id levelId is not valid. -or- The connector's domain is not Domain.​DomainHvac. -or- The points of startConnector and endPoint are equal.
Autodesk.Revit.Exceptions ArgumentNullException A non-optional argument was NULL
Autodesk.Revit.Exceptions DisabledDisciplineException None of the following disciplines is enabled: Mechanical Electrical Piping.
Autodesk.Revit.Exceptions InvalidOperationException Thrown when the new duct fails to connect with the connector.