SetProjection Method (AnalyticalElementSelector, StickElementProjectionY, ElementId)


Sets the analytical model projection to a preset value.

Namespace: Autodesk.Revit.DB.Structure
Assembly: RevitAPI (in RevitAPI.dll) Version: 2015.0.0.0 (2015.0.0.0)
Since: 2015

Syntax

C#
public void SetProjection(
	AnalyticalElementSelector selector,
	StickElementProjectionY projectionY,
	ElementId planeIdZ
)
Visual Basic
Public Sub SetProjection ( _
	selector As AnalyticalElementSelector, _
	projectionY As StickElementProjectionY, _
	planeIdZ As ElementId _
)
Visual C++
public:
void SetProjection(
	AnalyticalElementSelector selector, 
	StickElementProjectionY projectionY, 
	ElementId^ planeIdZ
)

Parameters

selector
Type: Autodesk.Revit.DB.Structure AnalyticalElementSelector
End of the analytical model.
projectionY
Type: Autodesk.Revit.DB.Structure StickElementProjectionY
Preset value for Analytical Model Stick projection Y.
planeIdZ
Type: Autodesk.Revit.DB ElementId
Plane on to which analytical model may be projected in Z direction. Plane identifies a Level, a Grid, or a Ref Plane.

Exceptions

Exception Condition
Autodesk.Revit.Exceptions ArgumentNullException A non-optional argument was NULL
Autodesk.Revit.Exceptions ArgumentOutOfRangeException A value passed for an enumeration argument is not a member of that enumeration

See Also