BuiltInFailures.EnergyAnalysisFailures Members


Provides a container of all Revit built-in FailureDefinitionId instances.

The BuiltInFailures EnergyAnalysisFailures type exposes the following members.

Properties

Name Description
Public property Static member ComputeRoomVolumeNotCheckedWarn
The setting for calculation of Volume Computations is not on. The analysis model produced will be approximate without the computation of Areas and Volumes
Public property Static member ModelWithNoConditionedSpacesWarn
The model has no conditioned spaces.
Public property Static member ModelWithNoOccupiedSpacesWarn
The model has no occupiable spaces.
Public property Static member NoRoofsRoomBoundingWarn
The energy analysis model does not contain any roof surfaces! If there are roofs in your model, please verify that they are room bounding, and make sure that the room offsets are high enough to include the roofs.
Public property Static member NoRoofsSpacesBoundingWarn
The energy analysis model does not contain any roof surfaces! If there are roofs in your model, please verify that they are space bounding, and make sure that the space offsets are high enough to include the roofs.
Public property Static member NoRoomBoundingElements
Can't create any energy analysis surfaces. There are no Room bounding elements defined in the current phase. Please check the Project Information settings.
Public property Static member NoRoomBoundingElementsWarn
Can't create any energy analysis surfaces. There are no Room bounding elements defined in the current phase. Please check the Project Information settings.
Public property Static member NoRoomsWarn
Revit was unable to identify any rooms. If you are sure that rooms have been created in the project, please check the Project Phase setting to verify that the Project Phase matches the phase in which rooms have been defined in your project.
Public property Static member NoSpaceBoundingElements
Can't create any energy analysis surfaces. There are no Space bounding elements defined in the current phase. Please check the Project Information settings.
Public property Static member NoSpaceBoundingElementsWarn
Can't create any energy analysis surfaces. There are no Space bounding elements defined in the current phase. Please check the Project Information settings.
Public property Static member NoSpaces
Revit was unable to identify any spaces. If you are sure that spaces have been created in the project, please check the Project Phase setting to verify that the Project Phase matches the phase in which spaces have been defined in your project.
Public property Static member NoSpacesWarn
Revit was unable to identify any spaces. If you are sure that spaces have been created in the project, please check the Project Phase setting to verify that the Project Phase matches the phase in which spaces have been defined in your project.
Public property Static member PlenumWithNoCeilingWarn
[Room] has Space Type set to Plenum but has no ceiling surface. A plenum must be separated from the space it serves by a ceiling.
Public property Static member ProblemWithLightingLoadWarn
[Room]'s lighting load is too high. This may be caused by an incorrect density value and must be corrected before this space can be included in the load calculations.
Public property Static member ProblemWithPeopleLoadWarn
[Room]'s number of people or people load (sensible or latent) is too high. This may be caused by an incorrect density value and must be corrected before this space can be included in the load calculations.
Public property Static member ProblemWithPowerLoadWarn
[Room]'s power load is too high. This may be caused by an incorrect density value and must be corrected before this space can be included in the load calculations.
Public property Static member RoomGeometryCannotFindFreeFacesBoundingElement
An error occurred while trying to find the free part of a face of the bounding geometry for [Room] when processing the room-bounding element [Name]. The free part of the face is found by subtracting the portions of the face that overlap various room-bounding element faces.
Public property Static member RoomGeometryCannotOverlapBoundingElement
An error occurred while trying to find the region where a face of the bounding geometry for [Room] overlaps a face of a room-bounding element [Name].
Public property Static member RoomGeometryCannotTrimBoundingElement
An error occurred while trimming the vertical shadow of a room-bounding element [Name] of the bounding geometry for [Room].
Public property Static member RoomNotPlacedWarn
[Family] is not placed. Physical properties such as area will display as "Not Placed" in schedules. You can place the [Family] using the option bar in the [Family] tool, or you can delete the [Family] in a schedule. [Room] will be ignored in the energy analysis model.
Public property Static member RoomNotUpperBoundedByElement
[Family] is not upper bounded by a roof, ceiling or floor element. This can result in incorrect adjacencies and voids in the analytical model. Please ensure that Upper Limit and Limit Offset for [Room] is set correctly.
Public property Static member RoomVolumeNegativeWarn
[Room] has a negative volume? [Room] will be ignored in the energy analysis model.
Public property Static member RoomVolumeNotComputedWarn
[Family] volume can't be computed. The bounding geometry (in 3D) can't be found for [Room]. [Room] will be ignored in the energy analysis model.
Public property Static member SpaceResolutionOutOfRange
Voxel size is out of range.
Public property Static member SurfaceResolutionOutOfRange
Pixel size is out of range.
Public property Static member UndefinedRooms
There are undefined Rooms in the model! Recommend creating a Room schedule and checking the Area parameter of each Room for warnings.
Public property Static member UndefinedSpaces
There are undefined Spaces in the model! Recommend creating a Space schedule and checking the Area parameter of each Space for warnings.
Public property Static member ZoneWithoutSpacesWarn
This zone has no spaces.