BuiltInFailures.MEPCalculationFailures Members


Provides a container of all Revit built-in FailureDefinitionId instances.

The BuiltInFailures MEPCalculationFailures type exposes the following members.

Properties

Name Description
Public property Static member AtLeastOneEquipmentOnDuty
There should be at least one equipment on duty.
Public property Static member ClassificationNotSetInFamily
A calculation did not complete because the Classification parameter in the Mechanical Equipment family is not set.
Public property Static member DemandFlowAndPressureLossNotSetInLossFamily
A calculation did not complete because the pressure loss value for element is not set. Select the element and enter a value for the Pressure Loss.
Public property Static member DemandFlowNotSetInLossFamily
A calculation did not complete because the Demand Flow for the element is not set.
Public property Static member DuctFittingAndAccessoryPressureDropCalculatorNotAvailable
Duct Fitting/Accessory Pressure Drop Calculator Not Available: [Calculator Name]
Public property Static member DuctPressureDropCalculatorNotAvailable
Duct Pressure Drop Calculator Not Available: [Calculator Name]
Public property Static member ExtraPumpSet
More than one parallel pump set defined for the same loop. Verify the flow distribution and delete the extra set, if desired.
Public property Static member FlowAndPressureCalculationMethodHasBeenImproved
During upgrade pressure drop calculations for hydronic piping systems using Simplified Colebrook or Custom Calculation methods have been recalculated using the Colebrook equation.
Public property Static member HydraulicSeparationAmbiguity
Unable to hydraulically separate until the system has flow.
Public property Static member HydraulicSeparationOfOneSystem
Unable to hydraulically separate the loop when both supply and return are assigned to the same system. Try again with both start and end selected.
Public property Static member InvalidFluidProperty
Some network components may have a flow value of 0 (zero), due to invalid value settings for fluid Dynamic Viscosity or Density. \nVerify that you have selected the correct fluid type and that the fluid Dynamic Viscosity and Density values are set correctly in the Mechanical Settings dialog.
Public property Static member InvalidNumberOfMechanicalEquipmentOnDuty
The number of on duty equipment must be less than or equal to the number of available equipments.
Public property Static member LoopSeparationNotCompleted
The loop separation is not completed yet. Only one side of the secondary/tertiary loop is separated. In order to correctly calculate the flow and pressure loss, please check and separate the other end of the loop.
Public property Static member MechanicalEquipmentSetBeingDeleted
The mechanical equipment set was deleted because it no longer contained any members.
Public property Static member Network_ElementNodeIsNotPartOfNetwork
The calculation could not be executed as configured. At least one of the elements in this network uses a node that is not part of the network.
Public property Static member Network_NodePropertyNotSet
The calculation could not be executed as configured. Specify a constraint property set for the following input or output node(s).
Public property Static member Network_NoInputNode
The calculation could not be executed as configured. Select an input node before analyzing this network.
Public property Static member Network_NoOutputNode
The calculation could not be executed as configured. Select an output node before analyzing this network.
Public property Static member Network_NoPressureConstraint
The calculation could not be executed as configured. Each network requires at least 1 pressure constraint. Specify the pressure constraint.
Public property Static member Network_NotEnoughElements
The calculation could not be executed as configured. Specify at least 3 elements before analyzing this network.
Public property Static member Network_NotEnoughNodes
The calculation could not be executed as configured. Specify at least 4 elements before analyzing this network.
Public property Static member Network_NotFullyConnected
The network is not well connected. Some elements may have unexpected flow and pressure loss values.
Public property Static member Network_OverConstrained
The calculation could not be executed as configured. The Pressure and Flow Rate combined constraint requires at least 2 other pressure or flow constraints. Specify additional constraints.
Public property Static member NetworkCanNotDeterminCriticalPath
The calculation has completed, but there may be an error in determining the critical path. Verify that demand flow is specified for all required elements.
Public property Static member NetworkDefaultToPressure
The network uses the default pressure.
Public property Static member NetworkDefaultToReynolds
The network uses the default Reynolds number.
Public property Static member NetworkEnergyEquationNotConverge
The energy calculation could not be performed.
Public property Static member NetworkErrorCalculatingPressure
The pressure calculation could not be performed.
Public property Static member NetworkErrorElementWithDownUpStreamNode
The network needs an input or output element to perform the calculation.
Public property Static member NetworkErrorExtractCurveData
The calculation could not be performed. Verify the pump curve data.
Public property Static member NetworkErrorModelTooBig
The size of the network exceeds the current limit for flow/pressure analysis. In the Mechanical Settings dialog, under Pipe Settings - Calculation, disable the option to Use analysis for closed loop hydronic networks.
Public property Static member NetworkErrorOverConstrained
The calculation could not be performed due to overconstrained flow condition in the network.
Public property Static member NetworkExtraPumpOutsideSet
Flow calculations do not calculate this pump together with the other pumps as one equipment set. Verify the flow distribution and add the pump to the equipment set, if desired.
Public property Static member NetworkInconsistentDemandFlow
The specified flow on this equipment is inconsistent with the other equipment in this branch. The branch flow is calculated based on the maximum specified value.
Public property Static member NetworkMinorLossNotConverge
The minor loss calculation could not be performed.
Public property Static member NetworkPressureNotConverge
The calculation could not be performed. Verify the pressure on the input element.
Public property Static member NetworkUnderConstrained
The network is under constrained. You may specify the design flow value in the missing branches, or cap the open ends.
Public property Static member PipeConnectorsAreNotLined
A calculation did not complete because the connectors used by this family to connect to the network are not linked.
Public property Static member PipeFittingAndAccessoryPressureDropCalculatorNotAvailable
Pipe Fitting/Accessory Pressure Drop Calculator Not Available: [Calculator Name]
Public property Static member PipePressureDropCalculatorNotAvailable
Pipe Pressure Drop Calculator Not Available: [Calculator Name]
Public property Static member PlumbingFlowCalculatorNotAvailable
Plumbing Flow Calculator Not Available: [Calculator Name]
Public property Static member PressureLossNotSetInLossFamily
A calculation did not complete because the pressure loss value for the source equipment is not set for the network.
Public property Static member PumpPressureNotComputed
The calculated pressure drop of this pump is not computed because the critical path is not a closed loop. Check to see if there are other pumps intended for use within a secondary/tertiary loop. Use the Add Separation tool to define the secondary/tertiary loop.
Public property Static member SeparationNotAtJunction
This hydraulic loop is not separated at any junction. Use the Remove Separation tool to clean up undesired hydraulic separations.
Public property Static member SeparationWithOddJunction
Hydraulic separation requires an even number of junctions on the header pipe for accurate calculations. Add or remove junctions to complete the separation.

See Also