Provides a container of all Revit built-in FailureDefinitionId instances.
The BuiltInFailuresConnectorFailures type exposes the following members.
Properties
| Name | Description | |
|---|---|---|
| AirTerminalCenterNotAligned | The center of the Air Terminal doesn't align at (0,0,0): align the Air Terminal Center to the Origin Defining Reference Planes could help to solve the problem. | |
| AllElementsRemovedFromCircuitGroup | [System] is empty and will be deleted. | |
| DisconnectedElements | Elements are disconnected! | |
| ElementAssignedToDefaultSystem | At least one connector on the highlighted element is currently assigned to the [Element Name]. In general items shouldn't be assigned to the Default Systems, but should be assigned as equipments or elements of a non-default system. Click the More Info button below for additional information on System Creation. | |
| ElementHasMultipleConnectors | Revit found one or more elements with multiple connectors. Select each element and then select the connectors to use for the analytical connection. | |
| ElementsAreDisconnected | Elements need to be disconnected. | |
| ElementsConnectedToParent | You have selected elements that are connected to a parent object in a System. These elements cannot be removed from the System. | |
| ElementsNeedToBeDisconnected | Elements need to be disconnected. | |
| ExistsForSelectedElement | Connections already exists for selected element. | |
| FittingMustBeOnDuct | The [Tap] must be attached to duct. | |
| FittingMustBeOnDuctWarn | The [Tap] must be attached to duct. | |
| FittingMustBeOnPipe | The [Tap] must be attached to pipe. | |
| FittingMustBeOnPipeWarn | The [Tap] must be attached to pipe. | |
| InvalidConnectionRef | The selected fitting has invalid connections and must be deleted to continue. | |
| InvalidConnector | The connector is invalid, the size cannot be determined from the connector. | |
| InvalidLoadClassificationValue | The load classification parameter cannot be empty. Please select a valid load classification element for the connector parameter and the associated family parameter. | |
| InvalidPowerFactorValue | The value for Power Factor must be between 0 and 1. | |
| JointGenderMismatch | The element has a connector with a fitting joint gender mismatch | |
| JointShapeMismatch | The element has a connector with a fitting joint shape mismatch | |
| JointSizeMismatch | The element has a connector with a fitting joint size mismatch | |
| JointTypeMismatch | The element has a connector with a fitting joint type mismatch | |
| LayoutConnector | [Unassigned System Type] on Connector [Index Number]. | |
| MismatchNoAvailableConnector | Cannot add [Element] to System. There is no available connector matching the System Type ([Type Name]) for the System. | |
| MultipleNetwork | Elements in [System Name] are not connected in a single physical network due to one or both of the following:\n- There are disconnects in the system's physical network.\n- Elements in the system are connected to more than one physical network. | |
| NetworkValidityError | The family is connected in a network and can no longer keep the connectivity. Disconnect the family from the network? | |
| NetworkValidityErrorWasDisconnected | The family is connected in a network and can no longer keep the connectivity. Disconnect the family from the network? | |
| NoLossDefined | No Loss Defined | |
| NoSupportKCoefficientTable | "K Coefficient from table" is not supported on connector for the element | |
| NotAllowedToModifyGroupElementsError | Connection to a group failed. Modification of elements within a group is not allowed. | |
| NotAllowedToModifyGroupElementsWarning | Connection to a group failed. Modification of elements within a group is not allowed. | |
| OpenConnector | The element has an open connector | |
| RbsNetworkValidityError | The family is connected in a network and can no longer keep the connectivity. | |
| RemoveConnectorLinksWarn | The links between connector [Index] and connector [Index], connector [Index] and connector [Index] are removed. | |
| RemoveConnectorLinkWarn | The link between connector [Index] and connector [Index] is removed. | |
| ShapesNotMatch | Shapes do not match. A connection could not be made. | |
| SizingCalculationFlowOnlyWarn | Some elements are not sized because the system calculation is flow only. You may change the system calculation level to size them again. | |
| SizingCalculationNoneWarn | Some elements are not sized because the system calculation level is none or performance. You may change the system calculation level to size them again. | |
| SizingFailed | Sizing failed. | |
| UnconnectedCircuit | The element has an unconnected circuit on its connector | |
| UnconnectedDevice | Device has an unconnected [Type Name] connector (index = [Index Number]). | |
| UndefinedConnector | Revit does not support Undefined connectors. The following have been replaced by the default connector: [Connector Element] |