BuiltInFailures.CurtainWallFailures Members


Provides a container of all Revit built-in FailureDefinitionId instances.

The BuiltInFailuresCurtainWallFailures type exposes the following members.

Properties

  NameDescription
Public propertyStatic memberAdjustEndCurtainWallParameterNoCorners
Can't put Corner Mullion at end joined to non-Curtain Wall.
Public propertyStatic memberAllGridSegmentsRemoved
Curtain grid lines must have at least one segment.
Public propertyStatic memberCannotApplyGridSpecification
It is not possible to apply the host family's grid specification to this instance.
Public propertyStatic memberCannotDivideCurtainGrid
Can't divide Curtain Grid by Grid Line.
Public propertyStatic memberCannotGroupCurtainGridHost
Curtain grid based elements cannot be grouped.
Public propertyStatic memberCannotHaveIndependentOverlappingGrids
Overlapping independent type associated gridlines are not allowed.
Public propertyStatic memberCannotPlaceSplitMullions
Could not determine how to place the highlighted mullions after the wall was split.
Public propertyStatic memberCannotSplitOldMullions
Split does not work on curtain walls containing mullions created in Revit prior to version 4.0. You may delete the mullions, place them again, and then proceed with splitting the wall.
Public propertyStatic memberCannotSwitchToCurtainWall
Can't switch type to Curtain Wall after Edit Elevation Profile.
Public propertyStatic memberCannotUseCornerMullion
Corner Mullions must be placed at a location that can have neighboring Panels that are not tangent. With the exception of Wall Join locations, Corner Mullions are not currently supported on the external boundaries of Curtain elements.
Public propertyStatic memberCurtainGridFaceCannotBeReparamForGridRotation
Curtain grids cannot be rotated exactly as requested. Push "Adjust Grids" to get the nearest valid rotation.
Public propertyStatic memberCurtainGridOffHost
Curtain grid has left its host.
Public propertyStatic memberCurtainSystemHostInvisible
Element defining the Curtain System is invisible in the current view.
Public propertyStatic memberDanglingCurtainWallCorner
A Corner Mullion has been placed at the end of a Curtain Wall that is not joined to another Curtain Wall. The angle of the Corner Mullion will default to 90 degrees.
Public propertyStatic memberDeletingCurtainSystemFaceGridLines
Deleting Grid Lines residing on faces that no longer are part of a Curtain System.
Public propertyStatic memberDependentGridlineMayBeDeleted
Type generated gridlines will become non-associated due to changes in the type. Press delete if you wish to remove them instead.
Public propertyStatic memberExceedMaxDrivenGridlines
Changes have been made that cause a curtain wall with type driven grid lines to exceed the maximum allowed number of type driven lines (200 in direction (1) and 200 in direction (2)). If you really need this many type driven grid lines, please split the affected wall before proceeding.
Public propertyStatic memberExessiveBeltDistance
The requested Measurement Line Offset would place the put the Measurement Line of the face boundaries.
Public propertyStatic memberGridlinesOutOfBounds
Manually placed curtain grid lines are on the wall edges or outside the wall boundaries.
Public propertyStatic memberGridlinesOutOfBoundsWarn
Manually placed curtain grid lines are on the wall edges or outside the wall boundaries.
Public propertyStatic memberGridlinesOutsideWillBeRedependent
Type associated curtain grid lines outside of the edited wall boundaries will be made dependent again in order that they remain on the wall.
Public propertyStatic memberGridlinesOverlap
Overlapping gridlines should be avoided, unless there are only two and one is host type dependent and the other is not.
Public propertyStatic memberGridlinesWerePushed
Panels and mullions created by a curtain grid were created with slight inaccuracies.
Public propertyStatic memberGridOutOfOrder
Curtain wall grid lines have changed order.
Public propertyStatic memberGridOutOfOrderError
Curtain wall grid lines have changed order.
Public propertyStatic memberGridOutsideWall
Curtain wall grid lines are outside wall. If you are trying to shorten the wall, please remove grid lines, including mullions on top of them.
Public propertyStatic memberInvalidSkipSegments
A curtain grid line had invalid removed segment data. When correcting data, Revit may have split curtain panels that should be combined.
Public propertyStatic memberMullionLostRefReorder
Mullions have lost references as a result of gridlines changing order. These mullions must be deleted.
Public propertyStatic memberMullionsWillBeDeleted
The Mullions between the Panels being joined will be deleted.
Public propertyStatic memberMultipleDominatingMullions
Multiple dominating mullions on a grid face may cause ambiguous automatic adjustment of margins.
Public propertyStatic memberMultipleIdsInCurtainSystem
A Curtain System cannot be based on faces from multiple elements.
Public propertyStatic memberMustReplacePanels
Missing Curtain Panels will be replaced with System Panels to complete command.
Public propertyStatic memberNegativeBeltDistance
Measurement Line Offset cannot be negative.
Public propertyStatic memberNonSupportedCurtainWall
Currently, only straight Walls with straight or arc edges are supported for non-rectangular Curtain Walls.
Public propertyStatic memberNoPanelsLoaded
No Curtain Panel Families loaded. Can't make arced Curtain Wall.
Public propertyStatic memberRequestOrphanMullionDeletion
Due to the changes in parameters of their hosts some mullions became non-type driven.
Public propertyStatic memberRuledCurtainElementLostCurves
Ruled Curtain System cannot be built. The Lines or Edges used to create it cannot be found.
Public propertyStatic memberTypePanelsFronNonRectCellsUnlocked
Loaded family curtain panels cannot be used in non-rectangular cells of the curtain host. Type-driven panels from non-rectangular cells were unlocked and left unchanged.