Properties

  NameDescription
Public propertyStatic memberAdditionalPartNotLoaded
An additional part was not loaded.
Public propertyStatic memberCannotConvertFlexPipeToPart
Cannot convert flex pipe to fabrication part.
Public propertyStatic memberCannotMatchFabricationHangerSizeToHost
The hanger cannot be re-sized to match the re-sized host.
Public propertyStatic memberFabDbChangeConn
Fabrication Database changes altered connectivity
Public propertyStatic memberFabDbOpenJobConn
Fabrication job imported had bad connectivity
Public propertyStatic memberFabDbSwapOut
Fabrication Database reload could not swap out for newer parts.
Public propertyStatic memberFabricationConfigurationCorrupted
It looks that the Fabrication Configuration %1!s! was corrupted, please check it at %2!s!.
Public propertyStatic memberFabricationHangerCannotBeSloped
A hanger cannot be sloped or placed on a sloped element.
Public propertyStatic memberFabricationHangerHostNotFound
The hanger will disconnect because we can't find the suitable host.
Public propertyStatic memberFabricationHangerNotConnectToHost
Fabrication Hanger didn't connect to the %s host.
Public propertyStatic memberFabricationHangerOutOfHost
The hanger is out of its host and will be disconnected.
Public propertyStatic memberFabricationHangerSizeNotMatch
The hanger size does not match the size of the host, so it can not be connected.
Public propertyStatic memberFabricationOutOfSizeCondition
The fabrication part size is not within the correct size range for the service button condition.
Public propertyStatic memberFabricationOverSizedCheck
Fabrication part is too large to fit on the sheet metal. Replace the part with multiple smaller parts, or notify the CAM operator.
Public propertyStatic memberFabricationPartCannotBeMirrored
Public propertyStatic memberFabricationPartCannotChangeServiceSizeWarning
The selected fitting(s) cannot successfully change service or change size. You must disconnect the connections on the fitting(s) and try again.
Public propertyStatic memberFabricationPartCannotChangeSlopeError
The connected fitting(s) cannot successfully change to the new slope value. You may try to disconnect the connections on the fitting(s) and try again.
Public propertyStatic memberFabricationPartCannotChangeTypeBadDimError
The selected fitting(s) cannot successfully change the type. The newly selected fabrication part may have badly configured dimensions or be constrained due to connected fitting(s). You may try to disconnect the connections on the fitting(s) and try again.
Public propertyStatic memberFabricationPartCannotChangeTypeBadDimUnConnError
The selected fitting(s) cannot successfully change the type. The newly selected fabrication part may have badly configured dimensions, resulting in bad geometry.
Public propertyStatic memberFabricationPartCannotChangeTypeError
The selected fitting(s) cannot successfully change the type. You must disconnect the connections on the fitting(s) and try again.
Public propertyStatic memberFabricationPartCannotChangeTypeIncompatError
The selected fitting(s) cannot successfully change the type. The newly selected fabrication part type either has no material or has badly configured dimensions, resulting in bad geometry. You may try to disconnect the connections on the fitting(s) and try again.
Public propertyStatic memberFabricationPartCannotChangeTypeIncompatUnConnError
The selected fitting(s) cannot successfully change the type. The newly selected fabrication part type either has no material or has badly configured dimensions, resulting in bad geometry.
Public propertyStatic memberFabricationPartCannotChangeTypeMisalignedError
The selected fitting(s) cannot successfully change the type. The newly selected fabrication part type has a problem with the angle dimension of the current fitting(s), resulting in bad geometry. You may try to disconnect the connections on the fitting(s) and try again.
Public propertyStatic memberFabricationPartCannotChangeTypeMisalignedUnConnError
The selected fitting(s) cannot successfully change the type. The newly selected fabrication part type has a problem with the angle dimension of the current fitting(s), resulting in bad geometry.
Public propertyStatic memberFabricationPartCannotChangeTypeUnConnError
The selected fitting(s) cannot successfully change the type.
Public propertyStatic memberFabricationPartCannotChangeTypeWarning
The selected fitting(s) cannot maintain connections to existing fabrication parts due to size, direction or angle differences. You must manually reconnect the open connections.
Public propertyStatic memberFabricationPartExceededAngleFlexToleranceWarning
The angle flex is greater than the maximum angle flex tolerance defined by the fabrication part. Connections with this part may not be properly aligned and may appear to be skewed.
Public propertyStatic memberFabricationPartExcludedPartWarning
There were fabrication parts needed to the make the connection that were excluded from the fabrication service causing the connection to fail. You may try to inlcude these fitting(s) and try again.
Public propertyStatic memberFabricationPartFitFailure
Fabrication Part Fitting Failed to Fit
Public propertyStatic memberFabricationPartFitFailWarning
Fabrication Part Fitting Failed to Fit
Public propertyStatic memberFabricationPartHasInvalidGeometry
The fabrication part either has no material or has badly configured dimensions, resulting in bad geometry.
Public propertyStatic memberFabricationPartInvalidConnection
Fabrication Part connection invalid and could not be automatically coupled.
Public propertyStatic memberFabricationPartInvalidSpecification
The part specification is invalid.
Public propertyStatic memberFabricationPartNoPartTypeFound
There are no fabrication part types found for the current Configuration and Service. Please select settings and reload the service to create the fabrication part types.
Public propertyStatic memberFabricationPartNotAttachedToStraight
The part must be attached to straight.
Public propertyStatic memberFabricationPartOptimizeInvalidConnection
No available couplings to connect standard lengths for this instance of straight.
Public propertyStatic memberFabricationRodDetachFromHangerError
The rod need to be detached from hanger.
Public propertyStatic memberFabricationRodsConnectionChangedWarning
The structural component that the hanger is attached to has changed to a different element.
Public propertyStatic memberFabricationRodsDisconnectedError
The hanger rod was disconnected because there is no structural component above.
Public propertyStatic memberFabricationRodsDisconnectedWarning
The hanger rod was disconnected because there is no structural component above.
Public propertyStatic memberFabricationServiceMismatch
Attempting to connect fabrication parts from different services.
Public propertyStatic memberFabricationStraigtLengthOversized
Fabrication straight exceeds the standard length. Use the Optimize Length command to adjust the length.
Public propertyStatic memberFixedFabricationPartNotChangeLength
Failed to change length of fixed part.
Public propertyStatic memberGroupedFabricationPartNotReposition
Failed to reposition part.
Public propertyStatic memberHangerProfileNotMatchWithHost
The defined hanger profile does not match with the host.
Public propertyStatic memberHangerWidthOutOfRange
The hanger width is too large to show.
Public propertyStatic memberInvalidConnectionsHaveBeenDisconnected
Invalid connections have been disconnected. Please reconnect them manually or use different fittings.
Public propertyStatic memberInvalidSelectionThereCannotBeOpenConnectors
Invalid selection there cannot be any open connectors for the design to fabrication part tool.
Public propertyStatic memberNoStructuralHostToAttachWarning
There is no structural component to attach the hanger rod to.
Public propertyStatic memberNotAllPartsWereConvertedUnsuportedFittingOffsets
Not all parts were converted. Eccentric transitions and taps that have offsets from the center line are unsupported and cannot be converted.
Public propertyStatic memberPinnedFabricationPartNotChangeExtension
Failed to change extension of part.
Public propertyStatic memberPinnedFabricationPartNotReposition
Failed to reposition part.
Public propertyStatic memberPlaceCutinFittingFailed
Failed to insert part.
Public propertyStatic memberSizeNotAvailableInFabricationService
Sizes:%1!s! in system %2!s! are not available in fabrication service:%3!s!, All available sizes are:\n%4!s!.
Public propertyStatic memberUneditableFabricationPartNotReposition
Failed to reposition part.