BuiltInFailures.ElectricalFailures Members


Provides a container of all Revit built-in FailureDefinitionId instances.

The BuiltInFailuresElectricalFailures type exposes the following members.

Properties

  NameDescription
Public propertyStatic memberAllSlotsOnPanelOccupied
All slots on panel: [Panel Name] are occupied. Some circuits will be disconnected from this panel.
Public propertyStatic memberBankDistanceSmallerThanDiameter
The distance value is smaller than the conduit diameter, please enter a larger value
Public propertyStatic memberCableTrayModified
The cable tray has been modified to be in the opposite direction or insufficient space to create the required fittings.
Public propertyStatic memberCannotAddMorePolesToCircuit
Empty slots are unavailable to hold the number of poles you specified for this spare. \nTo add more poles to this spare, you must free up slots by moving the circuits below the spare.
Public propertyStatic memberCannotAssignSecondaryDistSysToCircuit
Cannot assign or add [Element] to Circuit. There is no assigned secondary distribution system for [Element].
Public propertyStatic memberCannotConnectDifferentDesignOptsObjects
Cannot add or assign [Element] to circuit. Electrical objects belonging to different design options cannot be connected.
Public propertyStatic memberCannotCreatePanelScheduleDuetoNoDefaultTemplate
A panel schedule cannot be created for these panels. A default panel schedule template must be assigned for this template type.
Public propertyStatic memberCannotRemoveMembersInCircuitHavingParent
You have selected elements that are connected to a Panel object in a Circuit. These elements cannot be removed from the Circuit.
Public propertyStatic memberCircuitOverload
Total connected load for Circuit [Name] is exceeding 80% of the defined rating ([Rating Value]).
Public propertyStatic memberCircuitsOverlapAndDeleteSpareSpace
More than one Spare/Space falls onto the same slot. These Spares/Spaces will be deleted.
Public propertyStatic memberCircuitsOverlapDisconnectCircuits
More than one circuit falls onto the same slot. These circuits will be disconnected.
Public propertyStatic memberConduitModified
The conduit has been modified to be in the opposite direction or insufficient space to create the required fittings.
Public propertyStatic memberElementsBelongToOtherCircuit
You have selected elements that are already part of other Circuits that have assigned Panels. The elements you selected cannot be added to this Circuit.
Public propertyStatic memberFamilyMismatchCircuit
The family no longer matches the properties for the Circuit. Disconnect the family from the Circuit?
Public propertyStatic memberFeedThroughLugsIsDisabled
The feed through lugs option is unchecked.
Public propertyStatic memberFeedThroughLugsIsNotEnabledAndBindFormulaInFamily
Can't change connection type to Feed Through Lugs because Feed Through Lugs is unchecked. Enable Feed Through Lugs with related formula in family editor the Feed Through Lugs is mapped to. Select the panel -> Edit Family -> Family Types.
Public propertyStatic memberFeedThroughLugsIsNotEnabledAndBindGlobalParam
Can't change connection type to Feed Through Lugs because Feed Through Lugs is not enabled. Enable Feed Through Lugs by enabling the global parameter that Feed Through Lugs is mapping. Click Manage tab -> Settings panel -> Global Parameters.
Public propertyStatic memberFeedThroughLugsIsOccupied
The feed through lugs is in use by circuit [Element].
Public propertyStatic memberFeedThroughLugsIsOccupiedAndDisconnectOtherCircuits
The feed through lugs is occupied, so other circuits connected with feed through lugs will be disconnected from this panel [Panel Name].
Public propertyStatic memberInvalidApparentPowerDensity
The Apparent Power Density is invalid. Edit the Power Density and/or Power Factor to recalculate the Apparent Power Density.
Public propertyStatic memberInvalidNumberOfCircuitValueForSwitchPanel
The number of circuits on the switchboard currently exceeds the value you entered. Reduce the number of circuits on the equipment before changing this value.
Public propertyStatic memberInvalidNumwiresSinglephase
Invalid number of wires for single phase, only 2 and 3 are valid.
Public propertyStatic memberInvalidPathOfParallelConduits
Invalid path of parallel conduits
Public propertyStatic memberInvalidSpareSpace
The number of poles for a spare/space in a single phase, [wire] wires panel cannot exceed [value].
Public propertyStatic memberMaximumNumberOfPolesExceeded
You cannot add more poles to this spare, as doing so would exceed the maximum number of poles set for this equipment.
Public propertyStatic memberMismatchConnectorDistSysToCircuit
Cannot add [Element] to Circuit. The Type for the available connector does not match the Type ([Name]) for the Circuit.
Public propertyStatic memberMismatchNmbAssignedDistSysToCircuit
Cannot assign or add [Element] to Circuit. There is no assigned distribution system for [Element].
Public propertyStatic memberMismatchNmbOfPolesToCircuit
Cannot add [Element] to Circuit. The Number of Poles for [Element] does not match the Number of Poles ([Name]) for the Circuit.
Public propertyStatic memberMismatchPoleBrakesSlotsNumbers
The number of pole breakers may not be less than the number of occupied slots.
Public propertyStatic memberMismatchVoltageLineToLine
Cannot assign or add [Element] to Circuit. The Voltage ([Voltage Value]) for the Circuit is out of range for the Line to Line Voltage for [Element] (The Line to Line Voltage is specified in the assigned Distribution System).
Public propertyStatic memberMismatchVoltageToCircuit
Cannot add [Element] to Circuit. The Voltage for [Element] is out of range for the Voltage ([Voltage Value]) for the Circuit.
Public propertyStatic memberMissingOrInvalidWireSizeTable
Wire Size Table "[Fail Name]" is missing or invalid. Use Electrical Settings to select a valid Wire Size Table.
Public propertyStatic memberNoAvailableMatchingConnector
Cannot add [Element] to Circuit. There is no available connector matching the Type ([Type Name]) for the Circuit.
Public propertyStatic memberNotAllowedCableTrayConduitRotation
Don't allow to rotate a horizontal cable tray/conduit like this
Public propertyStatic memberNotEnoughAvailSlotsAndLugsOnPanel
You can't connect to panel [Panel Name] because there aren't enough slots and Feed Through Lugs is occupied. \nYou can increase the [ParameterName] to be greater than [Number] to connect through breaker slots or you can disconnect existing Feed Through Lugs connection.
Public propertyStatic memberNotEnoughAvailSlotsAndLugsOnSwitchPanel
You can't connect to switchboard [Panel Name] because there aren't enough space and circuit [Circuit Name] is set to Feed Through Lugs. \nYou can increase the number of circuits to be greater than [Number] to connect through breakers or you can disconnect circuit and select Feed Through Lugs again.
Public propertyStatic memberNotEnoughAvailSlotsOnPanel
You can't change the connection type to Breakers connect to panel [Panel Name] because there aren't enough slots. \nYou can increase the [ParameterName] to be greater than [Number] to connect through breaker slots or open the panel schedule and manually reshuffle non - consecutive slots.
Public propertyStatic memberNotEnoughRoomForParallelConduits
Due to changes in elevation, there is not enough room to generate all of the parallel conduits. As a result, some conduit segments have not been generated.
Public propertyStatic memberNotEnoughRoomForParallelPipes
Due to changes in elevation, there is not enough room to generate all of the parallel pipes. As a result, some pipe segments have not been generated.
Public propertyStatic memberNotEnoughSlotsOnlyLugAvailable
There aren't enough slots on panel [Panel Name], so the circuit will connect through Feed Through Lugs.
Public propertyStatic memberNotEnoughSlotsOnlyLugAvailableForSwitchPanel
There aren't enough space on switchboard [Panel Name], so the circuit will connect through Feed Through Lugs.
Public propertyStatic memberNotPositiveBendRadius
The value you entered for the bend radius is zero or a negative value. Enter a positive value.
Public propertyStatic memberNotSupportConcentricBend
Conduit with Fittings do not support Concentric Bend Radius, the bend radius of the conduit fittings will be same.
Public propertyStatic memberNumberOfCircuitFullOnSwitchPanel
You can't change the connection type to Breakers and connect to switchboard [Panel Name] because there aren't enough space. \nYou can increase the number of circuits to be greater than [Number] to connect through breakers.
Public propertyStatic memberObjsDemolished
Cannot assign [Element] to circuit. Objects that are demolished cannot be added to a circuit.
Public propertyStatic memberPanelMismatchCircuitType
Cannot assign [Element] to Circuit. The Type for the panel does not match the Type ([Name]) for the Circuit.
Public propertyStatic memberPanelMismatchDistSysWhenCircuitAssigned
The selected circuit was added to panel [Element], but the distribution system for the panel does not match the power connector definition on the panel.
Public propertyStatic memberReplaceSpareSpaceOnPanelBoard
Need to replace spare or space on panelboard.
Public propertyStatic memberReplaceSpareSpaceOnSwitchBoard
Need to replace spare or space on switchboard.
Public propertyStatic memberSelectedElementsArePartOfOtherCircuit
You have selected elements that are already part of other Circuits. They will be removed from the original Circuits and added to this one.
Public propertyStatic memberSmallBendRadius
The value you entered for the bend radius for conduit is too small. Enter a larger value.
Public propertyStatic memberUnsignedCircuit
Circuit is not assigned to a panel
Public propertyStatic memberVoltageIsOutOfRange
Cannot assign or add [Element] to Circuit. The Voltage ([Voltage Value]) for the Circuit is out of range for the Line to Ground Voltage for [Element] (The Line to Ground Voltage is specified in the assigned Distribution System)."
Public propertyStatic memberWireMaxSizeNonexistent
Cannot find max size in current wire type's material table.