Pipe |
Indicates whether to enable analysis for closed loop hydronic piping networks.
Namespace: Autodesk.Revit.DB.Plumbing
Assembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)

Property Value
Boolean
For closed loop hydronic piping networks, Revit can analyze flow and pressure values for supply and return loops. In the model, select a pump to see the results of the analysis in the Properties palette.
A closed loop hydronic piping network must contain:
- A single pump/circulator
- A single source, such as a boiler
- Multiple piping segments
- Multiple terminals, such as radiators.
A network may contain a direct return loop or a reverse return loop.