Panel |
Sets the value of the apparent load parameter for a spare
Namespace: Autodesk.Revit.DB.Electrical
Assembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)
public void SetSpareLoadValue(
int row,
int column,
ElementId idLoadParameter,
double value
) Parameters
- row Int32
- A row where the valid spare is
- column Int32
- A column where the valid spare is
- idLoadParameter ElementId
- One of 4 valid load parameters: RBS_ELEC_APPARENT_LOAD, RBS_ELEC_APPARENT_LOAD_PHASEA, RBS_ELEC_APPARENT_LOAD_PHASEB, RBS_ELEC_APPARENT_LOAD_PHASEC
- value Double
- The value of the spare's load for the given parameter
| Exception | Condition |
|---|---|
| ArgumentException | The load parameter id is not valid. |
| ArgumentNullException | A non-optional argument was null |
| ArgumentOutOfRangeException | The given value for value must be non-negative. |
| ArgumentsInconsistentException | The row column combination does not represent a valid spare. |