BuiltInFailures.RebarSystemFailures Class


Built In Failures Rebar System Failures Class

Failures related to rebar systems.
Inheritance Hierarchy
System Object
Autodesk.Revit.DB BuiltInFailures RebarSystemFailures

Namespace: Autodesk.Revit.DB
Assembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)
Syntax
public static class RebarSystemFailures

The BuiltInFailures RebarSystemFailures type exposes the following members.

Properties
Name Description
Public property Static member AreaReinforcementOutSideOfHost Area Reinforcement is sketched completely outside of its host.
Public property Static member AreaReinforcementRegenFail Can't regenerate Area Reinforcement.
Public property Static member AreaReinforcementsCollision Area Reinforcements are colliding. Aligning the Major Directions, or changing the Additional Offsets, can prevent collision.
Public property Static member AreaReinforcementWrongHost Area Reinforcement can be placed only in Structural Floors and straight Structural Walls.
Public property Static member BarsTooCloseNumber Bars are too close together. Decrease the Number Of Lines parameter.
Public property Static member BarsTooCloseSpacing Bars are too close together. Increase the Maximum Spacing parameter.
Public property Static member BarsTooSparseSpacing Bar spacing is greater than the size of the reinforced region. Decrease the Maximum Spacing parameter.
Public property Static member CannotPlaceAreaReinforcement Can't find a host for Area Reinforcement.
Public property Static member CannotPlaceAreaReinforcementWarn Can't find a host for Area Reinforcement.
Public property Static member CannotPlaceAreaReininforcement Can't find a host for Area Reinforcement.
Public property Static member CannotPlaceAreaReininforcementWarn Can't find a host for Area Reinforcement.
Public property Static member CannotPlacePathReinforcement Can't find a host for Path Reinforcement.
Public property Static member CannotPlacePathReinforcementWarn Can't find a host for Path Reinforcement.
Public property Static member CannotPlacePathReininforcement Can't find a host for Path Reinforcement.
Public property Static member CannotPlacePathReininforcementWarn Can't find a host for Path Reinforcement.
Public property Static member CannotUseAreaReinforcementHookTypeStyle At least one of the bars in the Area Reinforcement has a Bar Type or Shape that is incompatible with the Hook type. Check the Hook permissions for the Bar Type (see Hook Lengths) and the Hook and Rebar Shape styles.
Public property Static member CannotUsePathReinforcementHookTypeStyle At least one of the bars in the Path Reinforcement has a Bar Type or Shape that is incompatible with the Hook type. Check the Hook permissions for the Bar Type (see Hook Lengths) and the Hook and Rebar Shape styles.
Public property Static member DPartReinfDeletedEditDivision Edits to the model will cause some Reinforcement hosted on Parts to be deleted.
Public property Static member DPartReinforcementDeleted Reinforcement hosted on highlighted Parts will be deleted.
Public property Static member HostFlagAreaOff
Public property Static member HostFlagAreaOn The Area Reinforcement element was created in a document with the Host Structural Rebar setting on, and cannot be transferred into this document, which has the setting off.
Public property Static member HostFlagPathOff
Public property Static member HostFlagPathOn
Public property Static member InvalidLapSpliceInAreaReinforcement The instance major/minor lap lengths must be smaller than 1/2 of the overall length from the type in major and minor directions, respectively. The default values set for this parameters did not respect this criteria so they were automatically reset to the type values.
Public property Static member LessThanTwoBars Each reinforcement direction requires at least 2 bars. Please increase the number of bars.
Public property Static member PathReinforcementWrongHost Path Reinforcement can be placed only in Structural Floors and straight Structural Walls.
Public property Static member RebarSystemOffset Rebar Cover Side/Edge is too large for sketch. Bar placement may be inaccurate.
Public property Static member ThinHostFloor Rebar Cover Top and Bottom are too large for host.
Public property Static member ThinHostFloorError Rebar Cover Top and Bottom are too large for host.
Public property Static member ThinHostWall Rebar Cover Interior and Exterior are too large for host.
Public property Static member ThinHostWallError Rebar Cover Interior and Exterior are too large for host.
Top
See Also