Built |
Failures related to rebar systems.

Namespace: Autodesk.Revit.DB
Assembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)

The BuiltInFailures RebarSystemFailures type exposes the following members.

Name | Description | |
---|---|---|
![]() ![]() | AreaReinforcementOutSideOfHost | Area Reinforcement is sketched completely outside of its host. |
![]() ![]() | AreaReinforcementRegenFail | Can't regenerate Area Reinforcement. |
![]() ![]() | AreaReinforcementsCollision | Area Reinforcements are colliding. Aligning the Major Directions, or changing the Additional Offsets, can prevent collision. |
![]() ![]() | AreaReinforcementWrongHost | Area Reinforcement can be placed only in Structural Floors and straight Structural Walls. |
![]() ![]() | BarsTooCloseNumber | Bars are too close together. Decrease the Number Of Lines parameter. |
![]() ![]() | BarsTooCloseSpacing | Bars are too close together. Increase the Maximum Spacing parameter. |
![]() ![]() | BarsTooSparseSpacing | Bar spacing is greater than the size of the reinforced region. Decrease the Maximum Spacing parameter. |
![]() ![]() | CannotPlaceAreaReinforcement | Can't find a host for Area Reinforcement. |
![]() ![]() | CannotPlaceAreaReinforcementWarn | Can't find a host for Area Reinforcement. |
![]() ![]() | CannotPlaceAreaReininforcement | Can't find a host for Area Reinforcement. |
![]() ![]() | CannotPlaceAreaReininforcementWarn | Can't find a host for Area Reinforcement. |
![]() ![]() | CannotPlacePathReinforcement | Can't find a host for Path Reinforcement. |
![]() ![]() | CannotPlacePathReinforcementWarn | Can't find a host for Path Reinforcement. |
![]() ![]() | CannotPlacePathReininforcement | Can't find a host for Path Reinforcement. |
![]() ![]() | CannotPlacePathReininforcementWarn | Can't find a host for Path Reinforcement. |
![]() ![]() | CannotUseAreaReinforcementHookTypeStyle | At least one of the bars in the Area Reinforcement has a Bar Type or Shape that is incompatible with the Hook type. Check the Hook permissions for the Bar Type (see Hook Lengths) and the Hook and Rebar Shape styles. |
![]() ![]() | CannotUsePathReinforcementHookTypeStyle | At least one of the bars in the Path Reinforcement has a Bar Type or Shape that is incompatible with the Hook type. Check the Hook permissions for the Bar Type (see Hook Lengths) and the Hook and Rebar Shape styles. |
![]() ![]() | DPartReinfDeletedEditDivision | Edits to the model will cause some Reinforcement hosted on Parts to be deleted. |
![]() ![]() | DPartReinforcementDeleted | Reinforcement hosted on highlighted Parts will be deleted. |
![]() ![]() | HostFlagAreaOff | |
![]() ![]() | HostFlagAreaOn | The Area Reinforcement element was created in a document with the Host Structural Rebar setting on, and cannot be transferred into this document, which has the setting off. |
![]() ![]() | HostFlagPathOff | |
![]() ![]() | HostFlagPathOn | |
![]() ![]() | InvalidLapSpliceInAreaReinforcement | The instance major/minor lap lengths must be smaller than 1/2 of the overall length from the type in major and minor directions, respectively. The default values set for this parameters did not respect this criteria so they were automatically reset to the type values. |
![]() ![]() | LessThanTwoBars | Each reinforcement direction requires at least 2 bars. Please increase the number of bars. |
![]() ![]() | PathReinforcementWrongHost | Path Reinforcement can be placed only in Structural Floors and straight Structural Walls. |
![]() ![]() | RebarSystemOffset | Rebar Cover Side/Edge is too large for sketch. Bar placement may be inaccurate. |
![]() ![]() | ThinHostFloor | Rebar Cover Top and Bottom are too large for host. |
![]() ![]() | ThinHostFloorError | Rebar Cover Top and Bottom are too large for host. |
![]() ![]() | ThinHostWall | Rebar Cover Interior and Exterior are too large for host. |
![]() ![]() | ThinHostWallError | Rebar Cover Interior and Exterior are too large for host. |
