Provides a container of all Revit built-in FailureDefinitionId instances. 
 
The BuiltInFailures ElectricalFailures type exposes the following members.
Properties
| Name | Description | |
|---|---|---|
|     | AddingOtherConnectedMembersToCircuit |  You have selected elements that are connected to other elements. These elements will also be added to the Circuit.  | 
|     | AllSlotsOnPanelOccupied |  All slots on panel: [Panel Name] are occupied. Some circuits will be disconnected from this panel.  | 
|     | BankDistanceSmallerThanDiameter |  The distance value is smaller than the conduit diameter, please enter a larger value  | 
|     | CableTrayModified |  The cable tray has been modified to be in the opposite direction or insufficient space to create the required fittings.  | 
|     | CannotAssignSecondaryDistSysToCircuit |  Cannot assign or add [Element] to Circuit. There is no assigned secondary distribution system for [Element].  | 
|     | CannotConnectDifferentDesignOptsObjects |  Cannot add or assign [Element] to circuit. Electrical objects belonging to different design options cannot be connected.  | 
|     | CannotRemoveMembersInCircuitHavingParent |  You have selected elements that are connected to a Panel object in a Circuit. These elements cannot be removed from the Circuit.  | 
|     | CircuitOverload |  Total connected load for Circuit [Name] is exceeding 80% of the defined rating ([Rating Value]).  | 
|     | ConduitModified |  The conduit has been modified to be in the opposite direction or insufficient space to create the required fittings.  | 
|     | ElementsBelongToOtherCircuit |  You have selected elements that are already part of other Circuits that have assigned Panels. The elements you selected cannot be added to this Circuit.  | 
|     | FamilyMismatchCircuit |  The family no longer matches the properties for the Circuit. Disconnect the family from the Circuit?  | 
|     | InvalidNumwiresSinglephase |  Invalid number of wires for single phase, only 2 and 3 are valid.  | 
|     | InvalidPathOfParallelConduits |  Invalid path of parallel conduits  | 
|     | MismatchConnectorDistSysToCircuit |  Cannot add [Element] to Circuit. The Type for the available connector does not match the Type ([Name]) for the Circuit.  | 
|     | MismatchNmbAssignedDistSysToCircuit |  Cannot assign or add [Element] to Circuit. There is no assigned distribution system for [Element].  | 
|     | MismatchNmbOfPolesToCircuit |  Cannot add [Element] to Circuit. The Number of Poles for [Element] does not match the Number of Poles ([Name]) for the Circuit.  | 
|     | MismatchPoleBrakesSlotsNumbers |  The number of pole breakers may not be less than the number of occupied slots.  | 
|     | MismatchVoltageLineToLine |  Cannot assign or add [Element] to Circuit. The Voltage ([Voltage Value]) for the Circuit is out of range for the Line to Line Voltage for [Element] (The Line to Line Voltage is specified in the assigned Distribution System).  | 
|     | MismatchVoltageToCircuit |  Cannot add [Element] to Circuit. The Voltage for [Element] is out of range for the Voltage ([Voltage Value]) for the Circuit.  | 
|     | MissingOrInvalidWireSizeTable |  Wire Size Table "[Fail Name]" is missing or invalid. Use Electrical Settings to select a valid Wire Size Table.  | 
|     | NoAvailableMatchingConnector |  Cannot add [Element] to Circuit. There is no available connector matching the Type ([Type Name]) for the Circuit.  | 
|     | NotAllowedCableTrayConduitRotation |  Don't allow to rotate a horizontal cable tray/conduit like this  | 
|     | NotEnoughAvailSlotsOnPanel |  There are not enough slots available on panel: [Panel Name] for a circuit to be added. Please increase the maximum number of single pole breakers to be greater than [Number] or set it to 0.  | 
|     | NotEnoughRoomForParallelConduits |  Due to changes in elevation, there is not enough room to generate all of the parallel conduits. As a result, some conduit segments have not been generated.  | 
|     | NotEnoughRoomForParallelPipes |  Due to changes in elevation, there is not enough room to generate all of the parallel pipes. As a result, some pipe segments have not been generated.  | 
|     | NotPositiveBendRadius |  The value you entered for the bend radius is zero or a negative value. Enter a positive value.  | 
|     | NotSupportConcentricBend |  Conduit with Fittings do not support Concentric Bend Radius, the bend radius of the conduit fittings will be same.  | 
|     | ObjsDemolished |  Cannot assign [Element] to circuit. Objects that are demolished cannot be added to a circuit.  | 
|     | PanelMismatchCircuitType |  Cannot assign [Element] to Circuit. The Type for the panel does not match the Type ([Name]) for the Circuit.  | 
|     | SelectedElementsArePartOfOtherCircuit |  You have selected elements that are already part of other Circuits. They will be removed from the original Circuits and added to this one.  | 
|     | SmallBendRadius |  The value you entered for the bend radius for conduit is too small. Enter a larger value.  | 
|     | UnsignedCircuit |  Circuit is not assigned to a panel  | 
|     | VoltageIsOutOfRange |  Cannot assign or add [Element] to Circuit. The Voltage ([Voltage Value]) for the Circuit is out of range for the Line to Ground Voltage for [Element] (The Line to Ground Voltage is specified in the assigned Distribution System)."  |