UpdateFromIFC Method


Updates a Revit link type from an IFC file and loads the linked document.

Namespace: Autodesk.Revit.DB
Assembly: RevitAPI (in RevitAPI.dll) Version: 18.0.0.0 (18.0.0.420)
Since: 2015

Syntax

C#
public bool UpdateFromIFC(
	Document document,
	string ifcFilePath,
	string revitLinkedFilePath,
	bool recreateLink
)
Visual Basic
Public Function UpdateFromIFC ( _
	document As Document, _
	ifcFilePath As String, _
	revitLinkedFilePath As String, _
	recreateLink As Boolean _
) As Boolean
Visual C++
public:
bool UpdateFromIFC(
	Document^ document, 
	String^ ifcFilePath, 
	String^ revitLinkedFilePath, 
	bool recreateLink
)

Parameters

document
Type: Autodesk.Revit.DB Document
The document that contains Revit link.
ifcFilePath
Type: System String
The path of the IFC link to load. This must be a full path.
revitLinkedFilePath
Type: System String
The path of the Revit file to create to hold the IFC information. This must be a full path.
recreateLink
Type: System Boolean
If true, the Revit file will be updated based on the information in the IFC file. If false, the existing Revit file will be used.

Return Value

Returns true if the update succeeded, false otherwise.

Remarks

This function regenerates the input document. While the options argument allows specification of a path type, the input path argument must be a full path. Relative vs. absolute determines how Revit will store the path, but it needs a complete path to find the linked document initially. Note that the IFC file will not be stored directly in the document; it will instead by stored in an intermediate Revit document, whose location is given by revitLinkedFilePath.

Exceptions

Exception Condition
Autodesk.Revit.Exceptions ArgumentException document is not a project document. -or- The input path "ifcFilePath" does not represent an IFC file. -or- The document is a cloud model.
Autodesk.Revit.Exceptions ArgumentNullException A non-optional argument was NULL
Autodesk.Revit.Exceptions FileAccessException The model cannot be accessed due to lack of access privileges.
Autodesk.Revit.Exceptions FileArgumentNotFoundException There is not a valid Revit file at ifcFilePath's location
Autodesk.Revit.Exceptions InvalidOperationException Revit cannot customize worksets for this model.
Autodesk.Revit.Exceptions ModificationForbiddenException The document is in failure mode: an operation has failed, and Revit requires the user to either cancel the operation or fix the problem (usually by deleting certain elements). -or- The document is being loaded, or is in the midst of another sensitive process.