Provides a container of all Revit built-in FailureDefinitionId instances.
The BuiltInFailures ElectricalFailures type exposes the following members.
Properties
Name | Description | |
---|---|---|
![]() ![]() | AllSlotsOnPanelOccupied | All slots on panel: [Panel Name] are occupied. Some circuits will be disconnected from this panel. |
![]() ![]() | BankDistanceSmallerThanDiameter | The distance value is smaller than the conduit diameter, please enter a larger value |
![]() ![]() | CableTrayModified | The cable tray has been modified to be in the opposite direction or insufficient space to create the required fittings. |
![]() ![]() | CannotAssignSecondaryDistSysToCircuit | Cannot assign or add [Element] to Circuit. There is no assigned secondary distribution system for [Element]. |
![]() ![]() | CannotConnectDifferentDesignOptsObjects | Cannot add or assign [Element] to circuit. Electrical objects belonging to different design options cannot be connected. |
![]() ![]() | CannotCreatePanelScheduleDuetoNoDefaultTemplate | A panel schedule cannot be created for these panels. A default panel schedule template must be assigned for this template type. |
![]() ![]() | CannotRemoveMembersInCircuitHavingParent | You have selected elements that are connected to a Panel object in a Circuit. These elements cannot be removed from the Circuit. |
![]() ![]() | CircuitOverload | Total connected load for Circuit [Name] is exceeding 80% of the defined rating ([Rating Value]). |
![]() ![]() | ConduitModified | The conduit has been modified to be in the opposite direction or insufficient space to create the required fittings. |
![]() ![]() | ElementsBelongToOtherCircuit | You have selected elements that are already part of other Circuits that have assigned Panels. The elements you selected cannot be added to this Circuit. |
![]() ![]() | FamilyMismatchCircuit | The family no longer matches the properties for the Circuit. Disconnect the family from the Circuit? |
![]() ![]() | InvalidNumwiresSinglephase | Invalid number of wires for single phase, only 2 and 3 are valid. |
![]() ![]() | InvalidPathOfParallelConduits | Invalid path of parallel conduits |
![]() ![]() | MismatchConnectorDistSysToCircuit | Cannot add [Element] to Circuit. The Type for the available connector does not match the Type ([Name]) for the Circuit. |
![]() ![]() | MismatchNmbAssignedDistSysToCircuit | Cannot assign or add [Element] to Circuit. There is no assigned distribution system for [Element]. |
![]() ![]() | MismatchNmbOfPolesToCircuit | Cannot add [Element] to Circuit. The Number of Poles for [Element] does not match the Number of Poles ([Name]) for the Circuit. |
![]() ![]() | MismatchPoleBrakesSlotsNumbers | The number of pole breakers may not be less than the number of occupied slots. |
![]() ![]() | MismatchVoltageLineToLine | Cannot assign or add [Element] to Circuit. The Voltage ([Voltage Value]) for the Circuit is out of range for the Line to Line Voltage for [Element] (The Line to Line Voltage is specified in the assigned Distribution System). |
![]() ![]() | MismatchVoltageToCircuit | Cannot add [Element] to Circuit. The Voltage for [Element] is out of range for the Voltage ([Voltage Value]) for the Circuit. |
![]() ![]() | MissingOrInvalidWireSizeTable | Wire Size Table "[Fail Name]" is missing or invalid. Use Electrical Settings to select a valid Wire Size Table. |
![]() ![]() | NoAvailableMatchingConnector | Cannot add [Element] to Circuit. There is no available connector matching the Type ([Type Name]) for the Circuit. |
![]() ![]() | NotAllowedCableTrayConduitRotation | Don't allow to rotate a horizontal cable tray/conduit like this |
![]() ![]() | NotEnoughAvailSlotsOnPanel | There are not enough slots available on panel: [Panel Name] for a circuit to be added. Please increase the maximum number of single pole breakers to be greater than [Number] or set it to 0. |
![]() ![]() | NotEnoughRoomForParallelConduits | Due to changes in elevation, there is not enough room to generate all of the parallel conduits. As a result, some conduit segments have not been generated. |
![]() ![]() | NotEnoughRoomForParallelPipes | Due to changes in elevation, there is not enough room to generate all of the parallel pipes. As a result, some pipe segments have not been generated. |
![]() ![]() | NotPositiveBendRadius | The value you entered for the bend radius is zero or a negative value. Enter a positive value. |
![]() ![]() | NotSupportConcentricBend | Conduit with Fittings do not support Concentric Bend Radius, the bend radius of the conduit fittings will be same. |
![]() ![]() | ObjsDemolished | Cannot assign [Element] to circuit. Objects that are demolished cannot be added to a circuit. |
![]() ![]() | PanelMismatchCircuitType | Cannot assign [Element] to Circuit. The Type for the panel does not match the Type ([Name]) for the Circuit. |
![]() ![]() | SelectedElementsArePartOfOtherCircuit | You have selected elements that are already part of other Circuits. They will be removed from the original Circuits and added to this one. |
![]() ![]() | SmallBendRadius | The value you entered for the bend radius for conduit is too small. Enter a larger value. |
![]() ![]() | UnsignedCircuit | Circuit is not assigned to a panel |
![]() ![]() | VoltageIsOutOfRange | Cannot assign or add [Element] to Circuit. The Voltage ([Voltage Value]) for the Circuit is out of range for the Line to Ground Voltage for [Element] (The Line to Ground Voltage is specified in the assigned Distribution System)." |