Provides a container of all Revit built-in FailureDefinitionId instances. 
 
The BuiltInFailures RebarSystemFailures type exposes the following members.
Properties
| Name | Description | |
|---|---|---|
|     | AreaReinforcementOutSideOfHost |  Area Reinforcement is sketched completely outside of its host.  | 
|     | AreaReinforcementRegenFail |  Can't regenerate Area Reinforcement.  | 
|     | AreaReinforcementsCollision |  Area Reinforcements are colliding. Aligning the Major Directions, or changing the Additional Offsets, can prevent collision.  | 
|     | AreaReinforcementWrongHost |  Area Reinforcement can be placed only in Structural Floors and straight Structural Walls.  | 
|     | BarsTooCloseNumber |  Bars are too close together. Decrease the Number Of Lines parameter.  | 
|     | BarsTooCloseSpacing |  Bars are too close together. Increase the Maximum Spacing parameter.  | 
|     | BarsTooSparseSpacing |  Bar spacing is greater than the size of the reinforced region. Decrease the Maximum Spacing parameter.  | 
|     | CannotPlaceAreaReinforcement |  Can't find a host for Area Reinforcement.  | 
|     | CannotPlaceAreaReinforcementWarn |  Can't find a host for Area Reinforcement.  | 
|     | CannotPlaceAreaReininforcement |  Can't find a host for Area Reinforcement.  | 
|     | CannotPlaceAreaReininforcementWarn |  Can't find a host for Area Reinforcement.  | 
|     | CannotPlacePathReinforcement |  Can't find a host for Path Reinforcement.  | 
|     | CannotPlacePathReinforcementWarn |  Can't find a host for Path Reinforcement.  | 
|     | CannotPlacePathReininforcement |  Can't find a host for Path Reinforcement.  | 
|     | CannotPlacePathReininforcementWarn |  Can't find a host for Path Reinforcement.  | 
|     | CannotUseAreaReinforcementHookTypeStyle |  At least one of the bars in the Area Reinforcement has a Bar Type or Shape that is incompatible with the Hook type. Check the Hook permissions for the Bar Type (see Hook Lengths) and the Hook and Rebar Shape styles.  | 
|     | CannotUsePathReinforcementHookTypeStyle |  At least one of the bars in the Path Reinforcement has a Bar Type or Shape that is incompatible with the Hook type. Check the Hook permissions for the Bar Type (see Hook Lengths) and the Hook and Rebar Shape styles.  | 
|     | DPartReinfDeletedEditDivision |  Edits to the model will cause some Reinforcement hosted on Parts to be deleted.  | 
|     | DPartReinforcementDeleted |  Reinforcement hosted on highlighted Parts will be deleted.  | 
|     | HostFlagAreaOff | |
|     | HostFlagAreaOn |  The Area Reinforcement element was created in a document with the Host Structural Rebar setting on, and cannot be transferred into this document, which has the setting off.  | 
|     | HostFlagPathOff | |
|     | HostFlagPathOn | |
|     | LessThanTwoBars |  Each reinforcement direction requires at least 2 bars. Please increase the number of bars.  | 
|     | PathReinforcementWrongHost |  Path Reinforcement can be placed only in Structural Floors and straight Structural Walls.  | 
|     | RebarSystemOffset |  Rebar Cover Side/Edge is too large for sketch. Bar placement may be inaccurate.  | 
|     | ThinHostFloor |  Rebar Cover Top and Bottom are too large for host.  | 
|     | ThinHostFloorError |  Rebar Cover Top and Bottom are too large for host.  | 
|     | ThinHostWall |  Rebar Cover Interior and Exterior are too large for host.  | 
|     | ThinHostWallError |  Rebar Cover Interior and Exterior are too large for host.  |