BuiltInFailures.GenericMEPFailures Members


Provides a container of all Revit built-in FailureDefinitionId instances.

The BuiltInFailures GenericMEPFailures type exposes the following members.

Properties

Name Description
Public property Static member CapsWereAddedWarning
X caps were added.
Public property Static member CapWasAddedWarning
1 cap was added.
Public property Static member FailedToPlaceCapWarning
Failed to place cap on the open connector.
Public property Static member FlowConfigMismatch
[Element Name]: It is not possible to calculate the flow since all the components in this system have the flow configuration set to Preset or System. At least one component is required to have the flow configuration set to Calculated.
Public property Static member FlowDirectionMismatch
[Element Name]: It is not possible to calculate the flow since the flow direction mismatch. Please check flow direction on all equipment in this system.
Public property Static member InlineEndoflineMismatch
[Element Name]: It is not possible to calculate the flow since there is inline equipment that is configured as end of line. Please check equipment in this system and make sure that the equipment connectors used inline have a global system classification and a calculated flow configuration. Global equipment connectors used inline should always be linked to each other.
Public property Static member MaxWidthAndHeightReached
Maximum width and height reached during sizing
Public property Static member SegmentIsTooShort
The segment is too short.
Public property Static member SizingFailedZeroFlow
Sizing failed. Flow for section is 0.
Public property Static member ValidatePHSegmentConnWarning
The placeholder curve will not be able to connect to the required fittings for placeholder convert
Public property Static member ValidatePHSegmentLengthWarning
The placeholder curve is not long enough to support the required fittings for placeholder convert