BuiltInFailures.GenericMEPFailures Members


Provides a container of all Revit built-in FailureDefinitionId instances.

The BuiltInFailuresGenericMEPFailures type exposes the following members.

Properties

  NameDescription
Public propertyStatic memberCapsWereAddedWarning
X caps were added.
Public propertyStatic memberCapWasAddedWarning
1 cap was added.
Public propertyStatic memberFailedToPlaceCapWarning
Failed to place cap on the open connector.
Public propertyStatic memberFlowConfigMismatch
[Element Name]: It is not possible to calculate the flow since all the components in this system have the flow configuration set to Preset or System. At least one component is required to have the flow configuration set to Calculated.
Public propertyStatic memberFlowDirectionMismatch
[Element Name]: It is not possible to calculate the flow since the flow direction mismatch. Please check flow direction on all equipment in this system.
Public propertyStatic memberInlineEndoflineMismatch
[Element Name]: It is not possible to calculate the flow since there is inline equipment that is configured as end of line. Please check equipment in this system and make sure that the equipment connectors used inline have a global system classification and a calculated flow configuration. Global equipment connectors used inline should always be linked to each other.
Public propertyStatic memberMaxWidthAndHeightReached
Maximum width and height reached during sizing
Public propertyStatic memberSegmentIsTooShort
The segment is too short.
Public propertyStatic memberSizingFailedZeroFlow
Sizing failed. Flow for section is 0.
Public propertyStatic memberSplitElementDeletionWarning
The value specified for the Joint Gap exceeds the length of the split segment, so the segment will be deleted.
Public propertyStatic memberValidatePHSegmentConnWarning
The placeholder curve will not be able to connect to the required fittings for placeholder convert
Public propertyStatic memberValidatePHSegmentLengthWarning
The placeholder curve is not long enough to support the required fittings for placeholder convert