Create Method


Creates a new instance of pipe insulation.

Namespace: Autodesk.Revit.DB.Plumbing
Assembly: RevitAPI (in RevitAPI.dll) Version: 24.0.0.0 (24.0.0.0)
Since:  2012

Syntax

C#
public static PipeInsulation Create(
	Document document,
	ElementId pipeOrContentElementId,
	ElementId pipeInsulationTypeId,
	double Thickness
)
Visual Basic
Public Shared Function Create ( _
	document As Document, _
	pipeOrContentElementId As ElementId, _
	pipeInsulationTypeId As ElementId, _
	Thickness As Double _
) As PipeInsulation
Visual C++
public:
static PipeInsulation^ Create(
	Document^ document, 
	ElementId^ pipeOrContentElementId, 
	ElementId^ pipeInsulationTypeId, 
	double Thickness
)

Parameters

document
Type: Autodesk.Revit.DBDocument
The document.
pipeOrContentElementId
Type: Autodesk.Revit.DBElementId
The pipe, fitting, accessory ElementId to which insulation will be added.
pipeInsulationTypeId
Type: Autodesk.Revit.DBElementId
The pipe insulation type. If the input pipe insulation type is InvalidElementId, the default insulation type from the document will be used.
Thickness
Type: SystemDouble
The thickness of the insulation.

Return Value

The newly created pipe insulation.

Exceptions

ExceptionCondition
Autodesk.Revit.ExceptionsArgumentException This id does not represent a pipe, fitting, or accessory element. -or- This pipe insulation type is invalid. -or- Thickness is not valid for assignment to insulation or lining elements.
Autodesk.Revit.ExceptionsArgumentNullException A non-optional argument was null
Autodesk.Revit.ExceptionsDisabledDisciplineException None of the following disciplines is enabled: Mechanical Electrical Piping.
Autodesk.Revit.ExceptionsInvalidOperationException The document is in failure mode: an operation has failed, and Revit requires the user to either cancel the operation or fix the problem (usually by deleting certain elements).
Autodesk.Revit.ExceptionsModificationForbiddenException The document is in failure mode: an operation has failed, and Revit requires the user to either cancel the operation or fix the problem (usually by deleting certain elements). -or- The document is being loaded, or is in the midst of another sensitive process.
Autodesk.Revit.ExceptionsModificationOutsideTransactionException The document has no open transaction.