Built |
Failures about AnalyticalModel.
Namespace: Autodesk.Revit.DB
Assembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)
The BuiltInFailures AnalyticalModelFailures type exposes the following members.
| Name | Description | |
|---|---|---|
| | AdjustCurveTooShort | AdjustCurve is too short. |
| | AdjustEdgeTooShort | AdjustEdge is too short. |
| | AdjustEdgeTooShortErr | AdjustEdge is too short - continuable error version. |
| | AdjustEdgeTooShortWarn | AdjustEdge is too short. |
| | AnalyticalBeamSlabWarning | Beam and Slab Analytical Models do not have the same Analytical Projection Plane. |
| | AnalyticalCurvedPanelNotValid | Analytical Curved Panel is not valid. |
| | AnalyticalDiscrepancyWarning | Distance between Analytical and Physical Models of Structural Element is beyond tolerance of [Value] |
| | AnalyticalElementsInvalidAfterUpgrade | One or several analytical elements have become invalid during the upgrade process and will be deleted. |
| | AnalyticalGapWarning | Detected physical connection between Structural Elements, but did not detect Analytical intersection. |
| | AnalyticalLinkJoinedNodes | Analitycal Link is invalid. Reference nodes have been joined. |
| | AnalyticalLinkNotConnected | Analytical Link has lost one or more references. |
| | AnalyticalMemberInstability | Possible Member Instability, based on Release Conditions |
| | AnalyticalModelInstability | Possible Model Instability |
| | AnalyticalModelIsIncorrect | Analytical Model is not created for the structural element. |
| | AnalyticalPanelNotPlanar | Analytical Panel is not planar. |
| | AnalyticalPanelNotVisible | Analytical Panel is not visible in the current view. |
| | AnalyticalPhysicalCheckDone | Analytical / Physical Model Consistency check is complete. |
| | AnalyticalSupportCycleWarning | Circular support chain detected |
| | AnalyticalSurfaceCannotMove | Cannot move analytical surface. |
| | AnalyticalSurfaceCannotMoveByConnector | Cannot move analytical surface because it will disconnect the analytical nodes. |
| | AnalyticalTopBottomPlanesReversed | Analytical Top Projection Plane is partially or completely below Analytical Bottom Projection Plane. Please reset top and/or bottom planes to valid values. |
| | AutoDetectIgnoreLeaderWarning | Analytical Model for Structural Element has reset to its default location. |
| | BoundaryLinesIntersect | Boundary lines intersect. |
| | CannotCreateAnalyticalGeometry | Cannot construct Analytical Geometry. |
| | CannotKeepAnalyticalAdjustment | Analytical model Adjustment distance exceeds current Adjustment Snapping Distance. To adjust snap settings, go to the Structural Settings Dialog. |
| | CannotMakeAnalyticalGeometry | Cannot construct Analytical Geometry. |
| | CannotSlantAnalyticalWallError | Cannot slant a wall with an Analytical Model. Please disable the Analytical Model first. |
| | ContextualAnalyticalModelModeNotEnabled | Contextual Analytical Model not enabled. File open was canceled. |
| | HighestAssociatedLevelBelowLowestAssociatedLevel | The Highest Associated Level is set below the Lowest Associated Level |
| | LoadsMayBeNotUpToDate | Reactions defined as Internal Load (Is Reaction) may no longer be valid since the analytical model has changed. |
| | LowestAssociatedLevelAboveHighestAssociatedLevel | The Lowest Associated Level is set above the Highest Associated Level |
| | ProjectionPlaneInvalidWall | Projection plane becomes invalid for this wall. |
| | ProjectionPlanesNotIntersect | Can't project Analytical Model. Planes do not intersect each other. |
| | ProjectionPlanesParallel | Can't project Analytical Model. Two or more projection planes are parallel. |
| | StructAnalyticalErrorProjection | Can't project Analytical Model to Analytical Projection Surface |
| | StructuralElementMayNotBeSupported | Structural Element may not be supported -- verify support for Element. |
| | StructWallAnalyticalErrorAlign | Can't align Analytical Model with joined Walls. |
| | StructWallAnalyticalErrorConversion | Can't convert Edges to Analytical Model curves. |
| | SupportCheckDone | Member support check is complete. No unsupported elements detected. |
| | UnableToUpgradeAnalyticalElementGeometry | Unable to upgrade analytical element with incorrect geometry. To keep the elements, open Revit 2022 and correct the elements. |
| | WallAMLostAdjustmentReference | Wall Analytical Model has lost its adjustment reference. |