Provides a container of all Revit built-in FailureDefinitionId instances.
The BuiltInFailures ElectricalFailures type exposes the following members.
Properties
Name | Description | |
---|---|---|
AllSlotsOnPanelOccupied |
All slots on panel: [Panel Name] are occupied. Some circuits will be disconnected from this panel.
|
|
BankDistanceSmallerThanDiameter |
The distance value is smaller than the conduit diameter, please enter a larger value
|
|
CableTrayModified |
The cable tray has been modified to be in the opposite direction or insufficient space to create the required fittings.
|
|
CannotAssignSecondaryDistSysToCircuit |
Cannot assign or add [Element] to Circuit. There is no assigned secondary distribution system for [Element].
|
|
CannotConnectDifferentDesignOptsObjects |
Cannot add or assign [Element] to circuit. Electrical objects belonging to different design options cannot be connected.
|
|
CannotCreatePanelScheduleDuetoNoDefaultTemplate |
A panel schedule cannot be created for these panels. A default panel schedule template must be assigned for this template type.
|
|
CannotRemoveMembersInCircuitHavingParent |
You have selected elements that are connected to a Panel object in a Circuit. These elements cannot be removed from the Circuit.
|
|
CircuitOverload |
Total connected load for Circuit [Name] is exceeding 80% of the defined rating ([Rating Value]).
|
|
ConduitModified |
The conduit has been modified to be in the opposite direction or insufficient space to create the required fittings.
|
|
ElementsBelongToOtherCircuit |
You have selected elements that are already part of other Circuits that have assigned Panels. The elements you selected cannot be added to this Circuit.
|
|
FamilyMismatchCircuit |
The family no longer matches the properties for the Circuit. Disconnect the family from the Circuit?
|
|
InvalidNumwiresSinglephase |
Invalid number of wires for single phase, only 2 and 3 are valid.
|
|
InvalidPathOfParallelConduits |
Invalid path of parallel conduits
|
|
MismatchConnectorDistSysToCircuit |
Cannot add [Element] to Circuit. The Type for the available connector does not match the Type ([Name]) for the Circuit.
|
|
MismatchNmbAssignedDistSysToCircuit |
Cannot assign or add [Element] to Circuit. There is no assigned distribution system for [Element].
|
|
MismatchNmbOfPolesToCircuit |
Cannot add [Element] to Circuit. The Number of Poles for [Element] does not match the Number of Poles ([Name]) for the Circuit.
|
|
MismatchPoleBrakesSlotsNumbers |
The number of pole breakers may not be less than the number of occupied slots.
|
|
MismatchVoltageLineToLine |
Cannot assign or add [Element] to Circuit. The Voltage ([Voltage Value]) for the Circuit is out of range for the Line to Line Voltage for [Element] (The Line to Line Voltage is specified in the assigned Distribution System).
|
|
MismatchVoltageToCircuit |
Cannot add [Element] to Circuit. The Voltage for [Element] is out of range for the Voltage ([Voltage Value]) for the Circuit.
|
|
MissingOrInvalidWireSizeTable |
Wire Size Table "[Fail Name]" is missing or invalid. Use Electrical Settings to select a valid Wire Size Table.
|
|
NoAvailableMatchingConnector |
Cannot add [Element] to Circuit. There is no available connector matching the Type ([Type Name]) for the Circuit.
|
|
NotAllowedCableTrayConduitRotation |
Don't allow to rotate a horizontal cable tray/conduit like this
|
|
NotEnoughAvailSlotsOnPanel |
There are not enough slots available on panel: [Panel Name] for a circuit to be added. Please increase the maximum number of single pole breakers to be greater than [Number] or set it to 0.
|
|
NotEnoughRoomForParallelConduits |
Due to changes in elevation, there is not enough room to generate all of the parallel conduits. As a result, some conduit segments have not been generated.
|
|
NotEnoughRoomForParallelPipes |
Due to changes in elevation, there is not enough room to generate all of the parallel pipes. As a result, some pipe segments have not been generated.
|
|
NotPositiveBendRadius |
The value you entered for the bend radius is zero or a negative value. Enter a positive value.
|
|
NotSupportConcentricBend |
Conduit with Fittings do not support Concentric Bend Radius, the bend radius of the conduit fittings will be same.
|
|
ObjsDemolished |
Cannot assign [Element] to circuit. Objects that are demolished cannot be added to a circuit.
|
|
PanelMismatchCircuitType |
Cannot assign [Element] to Circuit. The Type for the panel does not match the Type ([Name]) for the Circuit.
|
|
SelectedElementsArePartOfOtherCircuit |
You have selected elements that are already part of other Circuits. They will be removed from the original Circuits and added to this one.
|
|
SmallBendRadius |
The value you entered for the bend radius for conduit is too small. Enter a larger value.
|
|
UnsignedCircuit |
Circuit is not assigned to a panel
|
|
VoltageIsOutOfRange |
Cannot assign or add [Element] to Circuit. The Voltage ([Voltage Value]) for the Circuit is out of range for the Line to Ground Voltage for [Element] (The Line to Ground Voltage is specified in the assigned Distribution System)."
|