OutsideAirChangesRatePerHour Property


The number of times the volume of air interchanges in the room in one hour.

Namespace: Autodesk.Revit.DB.Analysis
Assembly: RevitAPI (in RevitAPI.dll) Version: 21.0.0.0 (21.1.1.109)
Since: 2011

Syntax

C#
public double OutsideAirChangesRatePerHour { get; set; }
Visual Basic
Public Property OutsideAirChangesRatePerHour As Double
	Get
	Set
Visual C++
public:
property double OutsideAirChangesRatePerHour {
	double get ();
	void set (double value);
}

Remarks

Air Changes per hour is "unitless". It is a number. It is the number of times the air (the volume) interchanges in the room in one hour. This number is a format for expressing the requirement for airflow. The "flow" requirement for a room might be expressed, e.g., one room of 100 CF, and 3 Air Changes per Hour (ACH), would compute to 100 CF x 3 ACH / 60 min = 5 CFM.

Exceptions

Exception Condition
Autodesk.Revit.Exceptions ArgumentOutOfRangeException When setting this property: The outside airChangesRatePerHour does not fall within an appropriate range.

See Also