OutsideAirChangesRatePerHour Property


Energy Data Settings Outside Air Changes Rate Per Hour Property

The number of times the volume of air interchanges in the room in one hour.

Namespace: Autodesk.Revit.DB.Analysis
Assembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)
Syntax
public double OutsideAirChangesRatePerHour { get; set; }

Property Value

Double
Exceptions
Exception Condition
ArgumentOutOfRangeException When setting this property: The outside airChangesRatePerHour does not fall within an appropriate range.
Remarks
Air Changes per hour is "unitless". It is a number. It is the number of times the air (the volume) interchanges in the room in one hour. This number is a format for expressing the requirement for airflow. The "flow" requirement for a room might be expressed, e.g., one room of 100 CF, and 3 Air Changes per Hour (ACH), would compute to 100 CF x 3 ACH / 60 min = 5 CFM.