The number of times the volume of air interchanges in the room in one hour.
Namespace: Autodesk.Revit.DB.Analysis
Assembly: RevitAPI (in RevitAPI.dll) Version: 24.0.0.0 (24.0.0.0)
Since: 2011
Syntax
C# |
---|
|
Visual Basic |
---|
|
Visual C++ |
---|
|
Remarks
Air Changes per hour is "unitless". It is a number. It is the number of times the air (the volume) interchanges in the room in one hour. This number is a format for expressing the requirement for airflow. The "flow" requirement for a room might be expressed, e.g., one room of 100 CF, and 3 Air Changes per Hour (ACH), would compute to 100 CF x 3 ACH / 60 min = 5 CFM.
Exceptions
Exception | Condition |
---|---|
Autodesk.Revit.ExceptionsArgumentOutOfRangeException | When setting this property: The outside airChangesRatePerHour does not fall within an appropriate range. |