Document
New
|
Adds a new flexible duct into the document,
using a connector, point array and duct type.
Namespace: Autodesk.Revit.Creation
Assembly: RevitAPI (in RevitAPI.dll) Version: 27.0.4.0 (27.0.4.0)
public FlexDuct NewFlexDuct(
Connector connector,
IList<XYZ> points,
FlexDuctType ductType
)
Parameters
- connector Connector
- The connector to be connected to the duct, including the end points.
- points IList XYZ
- The point array indicating the path of the flexible duct.
- ductType FlexDuctType
- The type of the flexible duct.
Return Value
FlexDuctIf creation was successful then a new flexible duct is returned, otherwise an exception with failure information will be thrown.
| Exception | Condition |
|---|---|
| ArgumentNullException | Thrown when the input argument connector or points is . |
| InvalidOperationException | Thrown when the flexible duct cannot be created or regenerate fails. |
| ArgumentException | Thrown if the flexible duct type does not exist in the given document. |
If the connector is a fitting or equipment connector of the correct domain,
and if the connector's direction matches the direction of the flexible duct to be created,
the connectors will be automatically connected. A transition fitting will be added
at the connector(s) if necessary. If the connector's type, domain,
does not match the one of the input connector, no connection will be established.