Electrical
|
The ElectricalSystem type exposes the following members.

Name | Description | |
---|---|---|
![]() |
ApparentCurrent | The ApparentCurrent value of the Electrical System. |
![]() |
ApparentCurrentPhaseA | The ApparentCurrentPhaseA value of the Electrical System. |
![]() |
ApparentCurrentPhaseB | The ApparentCurrentPhaseB value of the Electrical System. |
![]() |
ApparentCurrentPhaseC | The ApparentCurrentPhaseC value of the Electrical System. |
![]() |
ApparentLoad | The ApparentLoad value of the Electrical System. |
![]() |
ApparentLoadPhaseA | The ApparentLoadPhaseA value of the Electrical System. |
![]() |
ApparentLoadPhaseB | The ApparentLoadPhaseB value of the Electrical System. |
![]() |
ApparentLoadPhaseC | The ApparentLoadPhaseC value of the Electrical System. |
![]() |
AssemblyInstanceId |
The id of the assembly instance to which the element belongs.
(Inherited from Element ) |
![]() |
BalancedLoad | Reports whether the BalancedLoad is on or off. |
![]() |
BaseEquipment |
The base panel or equipment of the system.
(Inherited from MEPSystem ) |
![]() |
BaseEquipmentConnector |
The connector within base equipment which is used to connect with system.
(Inherited from MEPSystem ) |
![]() |
BoundingBox |
Retrieves a box that circumscribes all geometry of the element.
(Inherited from Element ) |
![]() |
CableSize | The Cable Size of the Electrical System. |
![]() |
CableType | The Cable Type of the Electrical System. |
![]() |
Category |
Retrieves a Category object that represents the category or sub category in which the
element resides.
(Inherited from Element ) |
![]() |
CircuitConnectionType | The circuit connection type of the electrical system. |
![]() |
CircuitNamingIndex | The Circuit Naming Index where the Electrical System is located in its panel. The Circuit Naming Index is used to retrieve the Circuit Naming Index of the Electrical System. |
![]() |
CircuitNumber | The CircuitNumber of the Electrical System. |
![]() |
CircuitPathMode | The circuit path mode of the electrical system. |
![]() |
CircuitType | The circuit type of the Electrical System. |
![]() |
ConnectorManager |
Connector manager of the system.
(Inherited from MEPSystem ) |
![]() |
CreatedPhaseId |
Id of a Phase at which the Element was created.
(Inherited from Element ) |
![]() |
DemolishedPhaseId |
Id of a Phase at which the Element was demolished.
(Inherited from Element ) |
![]() |
DesignOption |
Returns the design option to which the element belongs.
(Inherited from Element ) |
![]() |
Document |
Returns the Document in which the Element resides.
(Inherited from Element ) |
![]() |
Elements |
Terminal elements in the system.
(Inherited from MEPSystem ) |
![]() |
Frame | The Frame value of the Electrical System. |
![]() |
Geometry |
Retrieves the geometric representation of the element.
(Inherited from Element ) |
![]() |
GroundConductorSize | The size of a Ground Conductor in the Electrical System. |
![]() |
GroundConductorsNumber | The GroundConductors Number of the Electrical System. |
![]() |
GroupId |
The id of the group to which an element belongs.
(Inherited from Element ) |
![]() |
HasCustomCircuitPath | Checks whether the electrical system circuit path has been customized. If not, the property CircuitPathMode cannot be set as Custom explicitly. |
![]() |
HasDesignParts |
Indicates if the system has one or more design parts.
(Inherited from MEPSystem ) |
![]() |
HasFabricationParts |
Indicates if the system has one or more fabrication parts.
(Inherited from MEPSystem ) |
![]() |
HasPathOffset | Whether the circuit path has a valid offset. |
![]() |
HasPlaceholders |
Indicates if the system has one or more placeholders.
(Inherited from MEPSystem ) |
![]() |
HotConductorSize | The size of a Hot Conductor in the Electrical System. |
![]() |
HotConductorsNumber | The HotConductors Number of the Electrical System. |
![]() |
Id |
A unique identifier for an Element in an Autodesk Revit project.
(Inherited from Element ) |
![]() |
IsBasePanelFeedThroughLugsOccupied | Checks if the feed through lugs of the base panel is already occupied. |
![]() |
IsEmpty |
Indicates if the system is empty or not.
(Inherited from MEPSystem ) |
![]() |
IsModifiable |
Identifies if the element is modifiable.
(Inherited from Element ) |
![]() |
IsMultipleNetwork |
Indicates if the system is well connected or not. The flag will enable the "Divide System" button.
(Inherited from MEPSystem ) |
![]() |
IsTransient |
Indicates whether an element is transient or permanent.
(Inherited from Element ) |
![]() |
IsValid |
Indicates if the system is valid or not.
atom AtomValidateSystem
default false
(Inherited from MEPSystem ) |
![]() |
IsValidObject |
Specifies whether the .NET object represents a valid Revit entity.
(Inherited from Element ) |
![]() |
Length | The Length value of the Electrical System. |
![]() |
LevelId |
The id of the level associated with the element.
(Inherited from Element ) |
![]() |
LoadClassificationAbbreviations | The LoadClassification Abbreviations used in the Electrical System. |
![]() |
LoadClassifications | The LoadClassifications used in the Electrical System. |
![]() |
LoadName | The LoadName of the Electrical System. |
![]() |
Location |
This property is used to find the physical location of an element within a project.
(Inherited from Element ) |
![]() |
Name |
A human readable name for the Element.
(Inherited from Element ) |
![]() |
NeutralConductorSize | The size of a Neutral Conductor in the Electrical System. |
![]() |
NeutralConductorsNumber | The NeutralConductors Number of the Electrical System. |
![]() |
OtherConductorSize | The size of an Other Conductor in the Electrical System. |
![]() |
OtherConductorsNumber | The OtherConductors Number of the Electrical System. |
![]() |
OwnerViewId |
The id of the view that owns the element.
(Inherited from Element ) |
![]() |
PanelName | The Panel name of the Electrical System. |
![]() |
Parameter BuiltInParameter |
Retrieves a parameter from the element given a parameter id.
(Inherited from Element ) |
![]() |
Parameter Definition |
Retrieves a parameter from the element based on its definition.
(Inherited from Element ) |
![]() |
Parameter Guid |
Retrieves a parameter from the element given a GUID for a shared parameter.
(Inherited from Element ) |
![]() |
Parameters |
Retrieves a set containing all of the parameters that are contained within the element.
(Inherited from Element ) |
![]() |
ParametersMap |
Retrieves a map containing all of the parameters that are contained within the element.
(Inherited from Element ) |
![]() |
PathOffset | The offset of the horizontal segments of the circuit path. |
![]() |
PhaseLabel | The circuit phase label used in the Electrical System. |
![]() |
Pinned |
Identifies if the element has been pinned to prevent changes.
(Inherited from Element ) |
![]() |
PolesNumber | The Poles Number of the Electrical System. |
![]() |
PowerFactor | The PowerFactor value of the Electrical System. |
![]() |
PowerFactorState | The PowerFactorState type of the Electrical System. |
![]() |
PressureLossOfCriticalPath |
The total pressure loss of the sections in critical path.
(Inherited from MEPSystem ) |
![]() |
Rating | The Rating value of the Electrical System. |
![]() |
RunsNumber | The Runs Number of the Electrical System. |
![]() |
SectionsCount |
The number of sections.
(Inherited from MEPSystem ) |
![]() |
SlotIndex | The Slots where the Electrical System is located in its panel. |
![]() |
StartSlot | The Start Slot where the Electrical System is located in its panel. |
![]() |
SystemType | The Electrical System Type of the Electrical System. |
![]() |
TrueCurrent | The TrueCurrent value of the Electrical System. |
![]() |
TrueCurrentPhaseA | The TrueCurrentPhaseA value of the Electrical System. |
![]() |
TrueCurrentPhaseB | The TrueCurrentPhaseB value of the Electrical System. |
![]() |
TrueCurrentPhaseC | The TrueCurrentPhaseC value of the Electrical System. |
![]() |
TrueLoad | The TrueLoad value of the Electrical System. |
![]() |
TrueLoadPhaseA | The TrueLoadPhaseA value of the Electrical System. |
![]() |
TrueLoadPhaseB | The TrueLoadPhaseB value of the Electrical System. |
![]() |
TrueLoadPhaseC | The TrueLoadPhaseC value of the Electrical System. |
![]() |
UniqueId |
A stable unique identifier for an element within the document.
(Inherited from Element ) |
![]() |
VersionGuid |
Get the element version Guid.
(Inherited from Element ) |
![]() |
ViewSpecific |
Identifies if the element is owned by a view.
(Inherited from Element ) |
![]() |
Voltage | The Voltage value of the Electrical System. |
![]() |
VoltageDrop |
Obsolete.
The VoltageDrop value of the Electrical System. |
![]() |
Ways | The circuit ways used in the Electrical System. |
![]() |
WireSizeString |
Obsolete.
The WireSize as a String of the Electrical System |
![]() |
WireType |
Obsolete.
The wire type of the Electrical System. |
![]() |
WorksetId |
Get Id of the Workset which owns the element.
(Inherited from Element ) |
